AMSEC ESL10 Operating Instructions

AMSEC ESL10 Operating Instructions

handle of the safe to the unlocked position and pull the door open.

Here are a few things to remember:

With each keystroke the red lamp on the keypad will flash and a chirp will be heard.

If 4 (four) incorrect combinations are entered, the lock will go into a "Penalty Lockout" for 15

minutes to prevent trial and error manipulation attempts at opening the lock. The red lamp

will flash once every 5 seconds during the penalty period. If you press any key during the

lockout period, the red lamp will flash with a chirp 8 times rapidly to indicate the lockout

Before keying the combination, be sure that the handle of the safe is in the fully locked

position to allow the lock to open freely.

If the lock fails to open or acts strange, replace the batteries with good quality fresh alkaline

9 volt batteries To replace the batteries, simply turn the keypad housing counter-clockwise

to the stop and pull it away from the base. Un-snap the old batteries and clip on the new

one. Position them in the pocket at the bottom of the housing and replace it watching that

the wires are not pinched. You should replace your batteries once a year to prevent

corrosion damage from leakage.

During the input sequence, if you make a mistake, you can press "C" to clear the previous

input and start over again.

The ESL10 uses a fixed length 6 (six) digit combination.

Use only your fingers to key the combination. Sharp objects will result in damage which is

not covered by the warranty.

If at any time during opening or combination changing the unit is left without input for 10

(ten) seconds, it returns to a resting condition. If this occurs during a combination change,

the Old Combination is retained.

At any time during opening or combination changing the unit will register the first 5 digits of

the combination into the "buffer" that receives input. The 6

pressed. For example, if your press C-1-2-3-4-5-7-4-5-2-7-6-# the program recognizes only

the C-1-2-3-4-5-6-# input. The last numeric key pressed continues to replace the one prior

until the "#" key is pressed to indicate completion. This is a security feature that allows you

to baffle an on-looker that may be trying to memorize your combination.

Continued on Reverse Side 

digit will be the last numeric key

You may change your combination any time you like and as many times as you like. Once your

safe is installed, you must change the combination to a number sequence other than the Factory

Combination of 1-2-3-4-5-6 to insure security.

Note: Combination changes should always be done with the door locked OPEN.

The input of a new combination is done by keying a "Change Key" code, followed by the Old

Combination to validate a change and then followed by entering the New Combination twice to

avoid a keying error. To change the combination, do the following:

Press the keys "C" and then "#". This is the "Change Key" that activates the change routine.

The unit responds with a short warbling tone (called the "good combo tone") and the red

lamp strobes with the tone.

Now key in the Old 6 digit combination, the "C" key may be used to clear an error in keying

at any time. Finish the input with a "#" key.

If the combination keyed matches the existing combination in permanent

memory, another short good combo tone is sounded. Proceed to "c."

If the combination keyed is incorrect, the unit responds with 4 short beeps (called

the bad combo tone) and returns to rest. The combination change routine is

aborted and the Old combination is retained. This also causes a count up for

Penalty Lockout.

Now key the first pass with the New 6 digit combination followed by a "#" key. Again, the "C"

key may be used to clear an error in keying at any time.

If the combination input is 6 digit in length, another short good combo tone is

sounded. Proceed to "d."

If the combination keyed is not 6 digits long, the unit responds with 4 short beeps

(called the bad combo tone) and returns to rest. The combination change routine

is aborted and the Old combination is retained.

Now key the second verify pass with the New 6 digit combination followed by a "#" key. As

before, the "C" key may be used to clear an error in keying at any time.

If the combination input matched the first pass, a long good combo tone is

sounded. The New Combination replaces the Old Combination in permanent

memory and the unit returns to a resting condition. Proceed to "e."

If the combination keyed does not match the first pass, the unit responds with the

bad combo tone and returns to rest. The combination change routine is aborted

and the Old combination is retained.

Test your New Combination several times prior to closing and locking the safe.

American Security Product Co.

Related Manuals for AMSEC ESL10

Electronic safe lock (4 pages)

Electronic safe lock (4 pages)

Electronic lock (10 pages)

Electronic lock (10 pages)

Biometric safe lock (20 pages)

5-button electronic lock (4 pages)

5-button electronic lock (4 pages)

Summary of Contents for AMSEC ESL10